= ZYNQ =
Booting the ZYNQ using TCL files & loading the bitstream is shown in scripts/trace/start.cmm.
= Troubleshooting =
== BUS ERROR after SYStem.Up ==
On old FSBL versions of Xilinx the DBG_CLK was not properly initialized. Which resulted in a BusError and possible debug session crash.
To prevent this use the following connection sequence:
SYStem.CPU ZYNQ-7000
; SYStem.CONFIG DAPIR/DR PRE/POST <values> if applicable
ETM.OFF
SYStem.Mode.Attach
; now verify that the DBG_CLK_CTRL is properly initialized.
; if not
; SLCR - UNLOCK WRITE
Data.Set ASD:0XF8000008 %LONG 0x0000DF0D
;DBG_CLK_CTRL - use ARM_PLL/6 ~ 111MHz with ARMPLL=666MHz
Data.Set ASD:0xF8000164 %LONG 0x623
; SLCR - LOCK WRITE
Data.Set ASD:0XF8000004 %LONG 0x0000767B
ETM.ON