Files
Gen4_R-Car_Trace32/2_Trunk/demo/arm/flash/am3715-emmc.cmm
2025-10-14 09:52:32 +09:00

191 lines
4.9 KiB
Plaintext

; --------------------------------------------------------------------------------
; @Title: eMMC FLASH Programming Script for AM3715
; @Description:
; eMMC FLASH(Numonyx, NAND16GXH) is connected
;
; Internal SRAM: 0x40200000
;
; SD/MMC Controller Register : 0x4809C100
;
; @Author: jjeong
; @Copyright: (C) 1989-2022 Lauterbach GmbH, licensed for use with TRACE32(R) only
; @Chip: AM3715
; @Keywords: Numonyx NAND16GXH flash eMMC
; --------------------------------------------------------------------------------
; $Id: am3715-emmc.cmm 10516 2022-02-02 11:39:30Z bschroefel $
LOCAL &arg1
ENTRY &arg1
&arg1=STRing.UPpeR("&arg1") // for example "PREPAREONLY"
&MMC_BASE=0x4809C100
PRINT "initializing..."
SYStem.CPU AM3715
SYStem.JtagClock 1Mhz ; start with a fix JTAG clock,
; otherwise every second system.up fails with an RTCK error
SYStem.Option DACR ON ; give Debugger global write permissions
SYStem.Option ResBreak OFF ; hardware dependent (see manual)
SYStem.Option WaitReset ON ; hardware dependent (see manual)
TrOnchip.Set DABORT OFF ; used by Linux for page miss!
TrOnchip.Set PABORT OFF ; used by Linux for page miss!
TrOnchip.Set UNDEF OFF ; my be used by Linux for FPU detection
SYStem.Option MMUSpaces OFF ; enable space ids to virtual addresses
SYStem.Up
SYStem.JtagClock RTCK ; switch to RTCK mode, after initialization
SETUP.IMASKASM ON ; lock interrupts while single stepping
; Target Setup: initialize DRAM controller and peripherals
; Either let the boot monitor setup the board
Go.direct
PRINT "target setup..."
WAIT 200.ms
Break.direct
IF STATE.RUN()
Break.direct
PER.Set.simple C15:0x1 %Long (Data.Long(C15:0x1)&~(0x1005)) ; disable MMU and cache
Data.Set 0x4809C12C %Long 0x000E3C07
Data.Set 0x4809C134 %Long 0x307f0033 ; enable the BRR bit
GOSUB disable_watchdog
GOSUB READ_ID_TEST
FLASHFILE.RESet
//FLASHFILE.CONFIG <MMC Controller Base> 0x0 0x0
FLASHFILE.CONFIG 0x4809C100 0x0 0x0
//FLASHFILE.target <Code_range> <Data_range> <Algorithm file>
FLASHFILE.TARGET 0x40200000++0x1FFF 0x40204000++0x1FFF ~~/demo/arm/flash/byte/emmc_omap.bin
Data.Set 0x4809C12C %Long 0x000E3C07 ; 400Khz , the Card identification mode
//Read FLASH Manufacture and Device ID
FLASHFILE.GETID
Data.Set 0x4809C12C %Long 0x000E0807 ; higher clock speed for the Data transfer mode
FLASHFILE.GETEXTCSD
//End of the test prepareonly
IF "&arg1"=="PREPAREONLY"
ENDDO
;FLASHFILE.DUMP 0x0 ; Read eMMC
;FLASHFILE.ERASE 0x0--0xFFFFF ; Erase eMMC
;FLASHFILE.LOAD * 0x0 ; Write eMMC
ENDDO
disable_watchdog:
; Enable Interface Clock
Data.Set 0x48004C10 %Long 0x20
; Enable functional clock
Data.Set 0x48004C00 %Long 0x20
; Check that module is IDLE
WAIT (Data.Long(SD:0x48004C20)&0x20)==0
; Disable watchdog timer
Data.Set SD:0x48314048 %Long 0x0000AAAA
WAIT (Data.Long(SD:0x48314034)&0x10)==0
Data.Set SD:0x48314048 %Long 0x00005555
WAIT (Data.Long(SD:0x48314034)&0x10)==0
; Check if the watchdog timer is running
IF (Data.Long(SD:0x48314048)!=0x00005555)
(
; Disable Watchdog 2
; Wait until reset complete
WAIT (Data.Long(SD:0x48314014)&0x01)!=0
; Disable 32Khz watchdog timer
Data.Set 0x48314048 %Long 0x0000AAAA
WAIT (Data.Long(SD:0x48314034)&0x10)==0
; Disable 32Khz watchdog timer
Data.Set 0x48314048 %Long 0x00005555
WAIT (Data.Long(SD:0x48314034)&0x10)==0
)
RETURN
READ_ID_TEST:
//MMC interface, not SD(HC)
//CMD0
RePeaT 2.
(
Data.Set &MMC_BASE+0x30 %Long 0xFFFFFFFF ;clear status
Data.Set &MMC_BASE+0x8 %Long 0x0 ;arg
Data.Set &MMC_BASE+0xc %Long 0x0 ;cmd
WAIT 10.ms
)
//CMD1
RePeaT 10.
(
Data.Set &MMC_BASE+0x30 %Long 0xFFFFFFFF ;clear status
Data.Set &MMC_BASE+0x8 %Long 0x40FF8000 ;arg
Data.Set &MMC_BASE+0xc %Long 0x01020000 ;cmd1
WAIT 100.ms
&resp=Data.Long(A:(&MMC_BASE+0x10))
//print "CMD1 resp: 0x" &resp
IF (&resp&0x80000000)==0x80000000
(
GOTO jump_cmd2
)
)
PRINT "CMD1 fail"
END
jump_cmd2:
//CMD2
Data.Set &MMC_BASE+0x30 %Long 0xFFFFFFFF ;clear status
Data.Set &MMC_BASE+0x8 %Long 0x0 ;arg
Data.Set &MMC_BASE+0xc %Long 0x02010000 ;cmd2
WAIT 10.ms
//CMD3
Data.Set &MMC_BASE+0x30 %Long 0xFFFFFFFF ;clear status
Data.Set &MMC_BASE+0x8 %Long 0x00010000 ; arg, MMC RCA is (0x0001<<16.)
Data.Set &MMC_BASE+0xc %Long 0x03020000 ;cmd3
WAIT 10.ms
//CMD10
Data.Set &MMC_BASE+0x30 %Long 0xFFFFFFFF ;clear status
Data.Set &MMC_BASE+0x8 %Long 0x00010000 ; arg, MMC RCA is (0x0001<<16.)
Data.Set &MMC_BASE+0xc %Long 0x0A010000 ;cmd10
WAIT 10.ms
//Response2
PRINT "CID register"
PRINT "[127:104] 0x" Data.Long(A:(&MMC_BASE+0x1c))
PRINT "[103:72] 0x" Data.Long(A:(&MMC_BASE+0x18))
PRINT "[71:40] 0x" Data.Long(A:(&MMC_BASE+0x14))
PRINT "[39:8] 0x" Data.Long(A:(&MMC_BASE+0x10))
RETURN